Thru Hole/Donut Load Cell with Welded Washer.
Capacities : +/- 1000 Lb.
Rated output : 2 mV/V.
Non Linearity : 2 %.
Central hole diameter : 0.95" [24.1 mm].
Material : Stainless Steel.
Cable output.
Custom Donut Load Cell.
Capacities : +/- 1200 Lb.
Rated output : 2 mV/V.
Non Linearity : 0.5 %.
Central hole diameter : 0.98" [25 mm].
Thread : M6x1.
Material : Stainless Steel.
Cable output.
Thru Hole/Donut Load Cell.
Capacities : +/- 100 Lb.
Rated output : 2 mV/V.
Non Linearity : 1 %.
Central hole diameter : 1.0" [25.4 mm].
Material : Stainless Steel.
Cable output.
Custom Thru Hole/Donut Load Cell.
Capacities : +/- 5000, 10 000 Lb.
Rated output : 3 mV/V.
Non Linearity : 0.5 %.
Central hole diameter : 26.4 mm.
Thread : 1 1/8-16.
Material : Stainless Steel.
Cable output.
Custom Square Flange Mount Thru Hole Load Cell.
Capacities : +/- 1000 Lb.
Rated output : 2 mV/V.
Non Linearity : 1 %.
Central hole diameter : 1.38" [35 mm].
Material : Stainless Steel.
RoHS Compliant.
Cable output.
Custom Flange Mount Thru Hole Spindle Load Cell For NSK BSF1462 Ball Screw Bearing , Tension & Compression.
Capacities : +/- 2000 Lb.
Rated output : ± 8 mA.
Non Linearity : 1 %.
Central hole diameter : 1.38" [35 mm].
Thread : M6x1.
Amplifier integrated.
Material : Stainless Steel.
Connector 6 Pin Bendix PT02E-10-6P Output.
Thru Hole/Donut Load Cell.
Capacities : +/- 250, 500, 1000 Lb.
Rated output : 2 mV/V.
Non Linearity : 3 %.
Central hole diameter : 1.47" [37.3 mm].
Material : Stainless Steel.
Cable output.
Custom Donut Load Cell.
Capacities : +/- 1000 Lb.
Rated output : 4...20 mA (3 wires).
Non Linearity : 0.5 %.
Center hole diameter : 1.8".
Material : Stainless Steel.
Connector output.
Options : Amplifier, Molex Connector.
Thru Hole/Donut Load Cell.
Capacities : +/- 30 000 Lb.
Rated output : 2 mV/V +/- 1%.
Non Linearity : 0.5 %.
Central hole diameter : 1.79" [45.46 mm].
Material : Stainless Steel.
Cable output.
QLA410: Custom Flange Style Thru Hole Load Cell.
Capacities : +/- 1600 Lb.
Rated output : 1.5 mV/V.
Non Linearity : 2 %.
Central hole diameter : 48 mm.
Operating temperature : -60 to 200 °F (-51 to 93 °C).
Material : Stainless Steel.
Cable output
Custom Flange Style Thru Hole Load Cell.
Capacities : +/- 1000 Lb.
Rated output : 2 mV/v.
Non Linearity : 1 %.
Dimensions : 2" [50.8 mm] ID x 4" [101.6 mm] OD x 0.25" [6.4 mm] H.
Material : Stainless Steel.
Cable Output.
Custom Donut Load Cell.
Capacities : +/- 20 000 Lb.
Rated output : 2 mV/V.
Non Linearity : 2 %.
Central hole diameter : 2.0" [50.8 mm].
Operating Temperature : -40 to 160 °F (-40 to 71 °C).
Material : Stainless Steel.
Cable output.
Custom Donut / Thru Hole Load Cell.
Capacities : +/- 2 000 Lb.
Rated output : ± 2 mV/V.
Non Linearity : 2 %.
Central hole diameter QLA209 : 2.0" [50.8 mm], QLA210 : 2 1/2" [63.5 mm].
Material : Stainless Steel.
Connector output.
Low profil Custom Load Washer.
High Capacities : +/- 90 000 Lb (400 KN).
Rated output : 1 mV/V.
Non Linearity : 3 %.
Central hole diameter : 2.04" [51.8 mm].
Material : Stainless Steel.
Cable output.
Custom Flange Style Thru Hole Load Cell.
Capacities : +/- 1000 Lb.
Rated output : 3 mV/v.
Non Linearity : 1 %.
Dimensions : 2.13" [54 mm] ID x 4" [101.6 mm] OD x 0.38" [9.5 mm] H.
Material : Stainless Steel.
Cable Output.
Custom Thru Hole Donut Load Cell.
Capacities : +/- 20 000 Lb.
Rated output : ± 2.5 mV/V.
Non Linearity : 2 %.
Center hole diameter : 2.166" [55 mm].
Material : Stainless Steel.
Connector output.
Custom Thru/Hole Donut Load Cell.
Capacities : +/- 50 000 Lb.
Rated output : ± 2 mV/V.
Non Linearity : 2 %.
Central hole diameter : 2 1/4" [57.2 mm].
Material : Stainless Steel.
Connector output.
Thru Hole/Donut Load Cell with Welded Washer.
Capacities : +/- 1000 Lb.
Rated output : 2 mV/V.
Non Linearity : 1 %.
Central hole diameter : 2.37" [60.2 mm].
Material : Stainless Steel.
Cable output.
Low Profile Custom Thru Hole/Donut Load Cell.
Capacities : +/- 5000 Lb.
Rated output : 2 mV/V.
Non Linearity : 2 %.
Central hole diameter : 2 3/8" [60.3 mm].
Material : Stainless Steel.
Cable output.
Custom Donut Load Cell.
Capacities : +/- 1000 Lb.
Rated output : 4-20 mA.
Non Linearity : 0.5 %.
Central hole diameter : 2.615" [66.4 mm].
Amplifier option.
Material : Stainless Steel.
Cable output
Custom Thru/Hole Donut Load Cell.
Capacities : +/- 40 000 Lb.
Rated output : ± 2.5 mV/V.
Non Linearity : 2 %.
Central hole diameter : 2.76" [70 mm].
Material : Stainless Steel.
Connector output.
Custom Donut Load Cell.
Capacities : 10 000 N.
Rated output : 1.5 mV/V.
Non Linearity : 3 %.
Central hole diameter : 2.84" [72 mm].
Material : Stainless Steel.
Cable output.
Flange Mount Thru Hole Compression Load Cell.
Capacities : +/- 15 000 Lb.
Rated output : 12 mA.
Non Linearity : 1 %.
Central hole diameter : 2.91" [74 mm].
Thread : M6x1.
Amplifier integrated 4-16 mA.
Material : Stainless Steel.
Connector Bendix PT02E-10-6P output.
Custom Thru/Hole Donut Load Cell.
Capacities : +/- 2 000 Lb.
Rated output : ± 2 mV/V.
Non Linearity : 2 %.
Central hole diameter : 3.2" [81.3 mm].
Material : Stainless Steel.
Connector output.
Custom Flange Style Thru Hole Load Cell.
Capacities : +/- 1200 Lb.
Rated output : 2 mV/v.
Non Linearity : 1 %.
Dimensions : 3.30" [83.8 mm] ID x 5.5" [139.7 mm] OD x 0.5" [12.7 mm] H.
Material : Stainless Steel.
Cable Output.
Custom Thru/Hole Donut Load Cell.
Capacities : +/- 40 000 Lb.
Rated output : ± 2 mV/V.
Non Linearity : 2 %.
Central hole diameter : 3.7" [94 mm].
Material : Stainless Steel.
Connector output.
Thru Hole/Donut Load Cell with Welded Washer.
Capacities : +/- 1000 Lb.
Rated output : 2 mV/V.
Non Linearity : 1 %.
Central hole diameter : 3.79" [96.3 mm].
Material : Stainless Steel.
Cable output.