Peel off test of flexible printed circuit
Flexible printed circuit is pulled to measure its peel strength for quality control and R&D.
It complies with the corresponding part of IEC 249-1: 1982 and IEC 326-2: 1990.
Products used:
- ZTS Series - Standard Model Digital Force Gauge.
- MX2 Series - Standard Type Vertical Motorized Test Stand.
- FC-21/20/40/21U/41U/21UQ - Film Grip.
- P90-200N - 90 degree Peel Test Fixture.
- CB-528 - Force Control Cable (MX2/EMX - ZT connection).
- Force Recorder Standard - Force-Time (Torque-Time) Graphing Software.
This video shows the testing image of objective sample. Some samples may not be suitable to measure with this configuration depending on their materials or shapes.
The example of product configuration is for your reference only. It varies depending on sample, measurement method and testing capacity. The products used in this video may differ from the example of product configuration.
Please select the right product model for the product configuration. Refer to the specification of each product for the compatibility.